0102030405
10kV Voltage Transformer JDZW Series - Reliable China Suppliers & Factory for Power Systems
Overview
JDZW series voltage transformers are indoor type, mostly using epoxy resin vacuum casting semi-enclosed or fully enclosed structure, suitable for power systems with rated frequency of 50Hz/60Hz and rated voltage of 10kV and below. They can convert high voltage into low voltage for energy metering, voltage monitoring and relay protection, provide accurate voltage signals for measurement and protection equipment, ensure safe and stable operation of the system, and comply with relevant electrical standards.
Product Features
Superior Insulation
Epoxy resin - cast insulation with fully - enclosed or semi - enclosed structure. Boasts excellent insulation performance, high impulse voltage resistance, moisture resistance, and corrosion resistance.
High Accuracy
Available in different accuracy classes (e.g., 0.2S, 0.5, etc.), providing precise voltage signals for metering and protection devices.
Compact Structure
Small size, light weight, easy to install. Flexible for various indoor installation spaces and directions.
Functional Adaptability
Suitable for 10kV systems. Enables voltage measurement, energy metering, and provides reliable signals for relay protection.
Safe & Reliable
Complies with electrical standards. Stable mechanical strength and insulation performance. Anti-tampering designs in terminal boxes.
Product Parameters
| Item | Parameter |
| Rated primary voltage | 10kV |
| Rated secondary voltage | 100V or 220V |
| Rated frequency | 50Hz |
| Power factor of load | COSϕ = 0.8 |
| Accuracy class | 0.2、0.5 etc |
| Rated output of 0.2 class | 15VA |
| Rated output of 0.5 class | 30VA |
| Limiting output | 200VA - 1000VA |
| Short duration power frequency withstand voltage | 12 |
| Lightning impulse withstand voltage | 42kV |
| Operating impulse withstand voltage | 75kV |
| Anti - Pollution grade | II |
| Ambient temperature | -5℃ to 40℃ |
| Altitude | ≤2000 meters |
| Winding temperature rise | ≤60K |
| Power - frequency withstand voltage (Primary to Secondary/Ground) | 3kV, 1min |
Frequently Asked Questions
What is the main application of the JDZW series voltage transformer?
The JDZW series is primarily used in indoor power systems (10kV and below) for energy metering, voltage monitoring, and relay protection by converting high voltage into precise low voltage signals.
What kind of insulation does this transformer use?
It utilizes epoxy resin vacuum casting, which provides a fully-enclosed or semi-enclosed structure for excellent insulation, moisture resistance, and corrosion resistance.
Can the JDZW series be installed outdoors?
No, the JDZW series is specifically designed as an indoor type voltage transformer.
What accuracy classes are available for this series?
It is available in various accuracy classes, including 0.2, 0.2S, and 0.5, to meet different metering and protection requirements.
Is there a limit to the installation altitude?
Yes, the JDZW series is designed for operation at altitudes less than or equal to 2000 meters.
What are the rated secondary voltage options?
The standard rated secondary voltage options are typically 100V or 220V, depending on the specific model and application needs.