China GGJ Low Voltage Capacitor Bank Factory - Top Suppliers for Power Factor Improvement and Reactive Power Compensation
Overview
GGJ series low voltage capacitor bank is specially designed for power distribution system with voltage of 220-690V and frequency of 50/60Hz. It performs reactive power compensation by automatically switching capacitor banks. It has reasonable structure and advanced technology. It is widely used in low voltage power grids to improve power factor, reduce reactive power loss and improve power supply quality. It is a new generation of power saving products.
Normal Operating Conditions
Altitude: ≤ 2000m
Ambient temperature: -20°C ~ +45°C
Relative humidity: ≤ 90% at 20°C
Installation environment: No harmful gases, vapors, non-conductive or explosive dust, and severe (mildew).
Main Technical Parameters
Main Features
Product Parameters
| Item | Units | Value |
|---|---|---|
| Rated Voltage | V | 220/400/690 |
| Rated Frequency | Hz | 50/60 |
| Applicable Voltage Range | - | 0.85-1.1 times the rated voltage |
| Maximum Permissible Current | - | 1.3 times the rated Current |
| Control Loop Quantity | - | 1-16 loops |
| Working Mode | - | automatic and continuous working |
Frequently Asked Questions (FAQ)
What is the primary function of the GGJ series low voltage capacitor bank?
The GGJ series capacitor bank is designed for reactive power compensation in systems with voltages of 220-690V. By automatically switching capacitor banks, it improves the power factor, reduces reactive power loss, and enhances overall power supply quality.
What are the ambient operating limits for this equipment?
It operates normally at altitudes of ≤ 2000m and within an ambient temperature range of -20°C to +45°C. The relative humidity should not exceed 90% at 20°C, and the environment must be free of harmful gases, explosive dust, or severe mildew.
What protection features does the GGJ series capacitor bank offer?
The system is equipped with multiple comprehensive protection mechanisms, including over-voltage, harmonic, over-compensation, system fault, phase loss, and over-load protection.
Will the system lose its configuration parameters during a power outage?
No. The intelligent controller features parameter memory, ensuring all settings are retained during a power failure. The system automatically resumes normal operation once the grid power is restored.
How does the capacitor bank handle grid interference?
The GGJ series has high anti-interference capabilities, allowing it to withstand up to 2000V interference pulses input directly from the power grid, which exceeds national professional standards.