China RM6-12 SF6 Gas-Insulated Ring Main Unit Suppliers - Reliable Medium-Voltage Switchgear Factory
Key Advantages
Excellent insulation and arc extinguishing performance
The RM6 device makes full use of the excellent insulation and arc extinguishing performance of SF6 gas to effectively prevent electrical faults, thereby ensuring the stable operation of the power system.
Versatile modular design
The device is designed with modularity as the core, and electrical components such as circuit breakers, load switches and earthing switches can be customized according to specific needs to provide customized power distribution solutions.
Space-saving structure
Its design focuses on compactness, which can be easily installed and used even in space-constrained environments, thereby optimizing the installation space.
Easy operation and maintenance
The device adopts a front operation design and does not require internal maintenance, which significantly improves the safety and convenience of operation. The simplified maintenance process helps to reduce operating and maintenance costs.
Environmental management
The device adopts an SF6 gas closed-loop system and an environmentally friendly design approach to minimize the impact on the environment. It is also carefully designed for easy recycling and disposal, which meets environmental requirements.
Comprehensive protection
The RM6 device provides a range of protection functions, including overload and short-circuit protection, to ensure that the power grid and connected equipment remain safe and stable under various conditions.
Product Parameters
| Item | Unit | C Module (Load Switch) |
F Module (Combined Apparatus) |
V Module (Vacuum Switch) |
Isolation/ Earthing Switch |
CB Module (Vacuum Circuit Breaker) |
Isolation/ Earthing Switch |
| Rated Voltage | KV | 12 | 12 | 12 | 12 | 12 | 12 |
| Rated Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 |
| Power Frequency Withstand Voltage (PhasetoPhase / Port) | kV | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 |
| Lightning Impulse Withstand Voltage | kV | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 |
| Rated Current | A | 630 | Note ¹ | 630 | 1250/630 | 1450 | |
| Breaking Capability | |||||||
| Rated Loop Breaking Current | A | 630 | |||||
| Rated Cable Charging Breaking Current | A | 10 | |||||
| Rated ShortCircuit Making Current (Peak) | A | 50 | |||||
| Rated Peak Withstand Current | kA | 50 | 80 | ||||
| Rated ShortTime Withstand Current | kA/35 | 20 | 20 | ||||
| Rated ShortCircuit Breaking Current | kA | 31.5 | 20 | 25 | |||
| Rated Transfer Current | A | 1700 | |||||
| Maximum Current of Equipped Fuse | A | 125 | |||||
| Loop Resistance | μΩ | ≤ 300 | ≤ 600 | ||||
| Mechanical Life | Times | 5000 | 3000 | 5000 | 2000 | 5000 | 5000 |
| Note ¹:Depends on the current rating of the fuse |