Key Advantages
Excellent Insulation & Arc Extinguishing
The RM6 device makes full use of the excellent insulation and arc extinguishing performance of SF6 gas to effectively prevent electrical faults, thereby ensuring the stable operation of the power system.
Versatile Modular Design
Designed with modularity at the core, electrical components such as circuit breakers, load switches, and earthing switches can be customized according to specific needs to provide tailored power distribution solutions.
Space-Saving Structure
Its design focuses on compactness, which can be easily installed and used even in space-constrained environments, thereby optimizing the installation space.
Easy Operation & Maintenance
Adopts a front operation design and does not require internal maintenance, significantly improving the safety and convenience of operation while reducing operating and maintenance costs.
Environmental Management
Utilizes an SF6 gas closed-loop system and an environmentally friendly design approach to minimize environmental impact. Carefully designed for easy recycling and disposal.
Comprehensive Protection
Provides a range of protection functions, including overload and short-circuit protection, to ensure that the power grid and connected equipment remain safe and stable under various conditions.
Product Parameters
| Item | Unit | C Module (Load Switch) |
F Module (Combined Apparatus) |
V Module (Vacuum Switch) |
Isolation / Earthing Switch |
CB Module (Vacuum Circuit Breaker) |
Isolation / Earthing Switch |
|---|---|---|---|---|---|---|---|
| Rated Voltage | kV | 12 | 12 | 12 | 12 | 12 | 12 |
| Rated Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 |
| Power Frequency Withstand Voltage (Phase-to-Phase / Port) | kV | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 |
| Lightning Impulse Withstand Voltage | kV | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 |
| Rated Current | A | 630 | Note ¹ | 630 | - | 1250/630 | 1450 |
| Breaking Capability | - | - | - | - | - | - | - |
| Rated Loop Breaking Current | A | 630 | - | - | - | - | - |
| Rated Cable Charging Breaking Current | A | 10 | - | - | - | - | - |
| Rated Short-Circuit Making Current (Peak) | A | 50 | - | - | - | - | - |
| Rated Peak Withstand Current | kA | 50 | 80 | - | - | - | - |
| Rated Short-Time Withstand Current | kA/3s | 20 | - | 20 | - | - | - |
| Rated Short-Circuit Breaking Current | kA | - | 31.5 | 20 | - | 25 | - |
| Rated Transfer Current | A | - | 1700 | - | - | - | - |
| Maximum Current of Equipped Fuse | A | - | 125 | - | - | - | - |
| Loop Resistance | μΩ | ≤ 300 | ≤ 600 | - | - | - | - |
| Mechanical Life | Times | 5000 | 3000 | 5000 | 2000 | 5000 | 5000 |
| Note ¹: Depends on the current rating of the fuse | |||||||
Frequently Asked Questions (FAQ)
What are the main functions of the RM6 device?
The RM6 device provides comprehensive protection, including overload and short-circuit protection, using SF6 gas for insulation and arc extinguishing to keep the power grid safe.
Is the RM6 device customizable?
Yes, it features a versatile modular design allowing custom configurations of circuit breakers, load switches, and earthing switches according to specific distribution needs.
Can this equipment be installed in tight spaces?
Absolutely. The RM6 features a space-saving, compact design that allows easy installation and optimization in space-constrained environments.
How easy is it to maintain the RM6 device?
It is designed for easy operation and maintenance, featuring a front operation layout and requiring no internal maintenance, which helps lower operating costs.
What is the environmental impact of the SF6 gas used?
The RM6 utilizes an SF6 gas closed-loop system designed to minimize environmental impact and is structured for easy recycling and disposal at the end of its life cycle.