China RM6-40.5 SF6 Gas-Insulated Ring Main Unit Switchgear - Reliable Factory Suppliers for 40.5kV Distribution Systems
Overview
BKRM6-40.5 metal ring network switchgear (hereinafter referred to as the inflatable cabinet) is suitable for use in three-phase AC 50Hz, rated voltage 40.5kV distribution systems. It is used for breaking and closing load currents, overload currents, overload currents, and short circuits. It can also disconnect capacitive loads such as no-load transformers, overhead lines at a certain distance, cable lines, and capacitor banks. It plays a role in the distribution, control, and protection of electrical energy in the power system.
BKRM6-40.5 adopts a fully sealed structure, and all primary charged components are sealed in a stainless steel welded chamber with a protection level of IP67. A multi circuit ring network switchgear that can adapt to various harsh environmental conditions such as humidity, salt spray, floods, heavy pollution, etc., and has high operational safety and reliability. Widely used in industrial parks, streets, airports, residential areas, bustling commercial centers, etc., it is an ideal equipment for distribution network automation. It is also used for compact box type substations, cable branch boxes, switch stations, wind power stations, subway and tunnel lights.
BKRM6-40.5 has multiple modules that can be combined according to user requirements, providing multiple combination methods to adapt to the vast majority of situations that require ring network units Up to 4 modules can be configured in the same SF6 gas chamber. When there are more than 4 units in the module, an extended busbar can be used to connect the switchgear.
Key Advantages
Fully Sealed & Insulated
All live parts are sealed in a 304 stainless steel chamber filled with SF6 gas (1.4 bar, IP67), ideal for harsh, humid, or dusty environments like mines.
High Safety & Reliability
Features reliable pressure relief channels, passing 20kA/0.5s internal arc tests. Mechanical interlocking prevents accidental entry into live intervals.
Maintenance-Free & Long Life
Designed for a 30-year operational lifespan without switch maintenance. Annual leakage rate of SF6 gas is ≤ 0.1%.
Compact Structure
Modules are only 500mm wide (except metering/PT cabinets). Consistent ground height for cable sleeves simplifies installation.
Intelligent Control
Equipped with optional intelligent control devices for remote protection, monitoring, and distribution automation support.
Transformer Protection
Offers load switch fuse combinations for transformers ≤ 1600kVA, and circuit breakers with relays for all capacities.
Environmental Protection
Developed with eco-friendly materials and zero-leakage cleaning technology. 90% to 95% of materials are recyclable.
Product Parameters
| Item | Unit | C Module | F Module | V Module | CB Module | ||
| (Load Switch) | (Combined Apparatus) | (Vacuum Switch) | Isolation/ Earthing Switch |
(Vacuum Circuit Breaker) | Isolation/ Earthing Switch |
||
| Rated Voltage | kV | 36/40.5 | 35/40.5 | 36/40.5 | 36/40.5 | 36/40.5 | 36/40.5 |
| Power Frequency Withstand Voltage | kV | 70/95 | 70/95 | 70/95 | 70/95 | 70/95 | 70/95 |
| Isolation Port Voltage | kV | 80/110 | 80/110 | 80/110 | 80/110 | ||
| Lightning Impulse Withstand Voltage (Isolation Port) | kV | 170/185 | 170/185 | 170/185 | 170/185 | 170/185 | 170/185 |
| Isolation Port (kV) | kV | 195/215 | 195/215 | 195/215 | |||
| Rated Current | A | 630/6301 | 200/200 | 630/630 | |||
| Breaking Capability | |||||||
| Active Load | A | 630/6330 | 200/200 | ||||
| Loop Current Breaking | A | 630/630 | 200/200 | ||||
| NoLoad Cable Charging | A | 20/21 | 20/21 | 50(C1) | |||
| Ground Fault | A | 60/63 | 60/63 | ||||
| Ground Fault Cable Charging | A | 35/36 | 35/36 | ||||
| Transfer Current | A | 840/750 | |||||
| ShortCircuit Breaking Current | kA | 20(Expected) | 20/20[EI,S] | ||||
| Making Capacity | kA | 50/50 | |||||
| (50 Times) | 50/50 | ||||||
| (50 Times) | 50(Expected) | 2.5/2.5 | |||||
| (5 Times) | 50/50 | 50/50 | |||||
| Class (Electrical Life) | E3/E2 | E2/E2 | / | E2/E2 | E2/E2 | E2/E2 | |
| 3s ShortTime Withstand Current | kA | 20/20 | 20/20 | Limited by HighVoltage Fuse | 20/20 | 20/20 | |
| Internal Arc Classification IAC AFL. 1s | 20/20 | 20/20 | 20/20 | ||||
Frequently Asked Questions
The BKRM6-40.5 inflatable cabinet is designed for three-phase AC distribution systems operating at a frequency of 50Hz and a rated voltage of 40.5kV.
Featuring a fully sealed structure with an IP67 protection rating, the switchgear is highly resistant to humidity, salt spray, floods, heavy dust, and air pollution, making it suitable for mines and industrial areas.
No, the BKRM6-40.5 is designed for a service lifespan of 30 years, during which the main switch is completely maintenance-free. The annual SF6 gas leakage rate is kept at ≤ 0.1%.
All live components are enclosed in gas chambers that have passed the 20kA/0.5s internal arc fault test. Additionally, reliable mechanical interlocks prevent accidental access to live intervals.
It offers two main methods: a load switch fuse combination for transformers rated at 1600kVA and below, and vacuum circuit breakers with relay protection for transformers of various capacities.
Yes, it uses zero-leakage cleaning technology during production, and between 90% to 95% of the materials used in the switchgear can be recycled at the end of its life cycle.