China SC (B) 11 Dry-Type Power Transformers - Energy-Saving, Reliable Solutions from Trusted Suppliers and Factory
Product Advantages
Loss and Energy Efficiency
The no-load loss has decreased by about 12%, making it more energy-efficient and environmentally friendly. Long term operation can save more electricity costs, improve economic efficiency, and meet the current development needs of energy conservation and consumption reduction.
Mechanical and Electrical Performance
Higher mechanical strength, better short-circuit resistance, less likely to be damaged in the face of short-circuit faults, and improved operational reliability; High insulation level and good lightning impulse resistance, which can better protect equipment and reduce the probability of failure under overvoltage conditions such as lightning.
Operation and Maintenance
The maintenance free feature is more prominent, with excellent moisture-proof performance. It can operate in a 100% humidity environment without preheating before operation, and intermittent operation does not require dehumidification treatment, reducing operation and maintenance costs and workload.
Volume and Noise
Small in size, lightweight, easy to transport and install, can save installation space; Reduced noise level, quieter operation, and reduced noise interference to the surrounding environment.
Heat Dissipation and Overload
With strong heat dissipation capabilities, it can achieve 150% rated load operation under cold air conditions, ensuring stable power supply during short-term load peaks and improving equipment applicability and flexibility.
Technical Parameters
| Rated Capacity kVA | Voltage Combination kV | Connection Symbol | No-load Loss kW | Load Loss kW | No-load Current % | Short-circuit Impedance % | Weight kg | Outer Dimensions mm (L×B×H) | Rail Gauge mm | |||
| High Voltage | Low Voltage | Tank Body | Oil Weight | Total Weight | ||||||||
| 200 | 10.5 10 6.3 6 |
6.3 3.15 3 |
Yd11 Dy11 |
0.340 | 3.15 | 1.8 | 4.5 | 650 | 160 | 1000 | 1180×740×1270 | 660/660 |
| 250 | 0.400 | 3.60 | 1.7 | 770 | 200 | 1190 | 1230×780×1340 | |||||
| 315 | 0.480 | 4.30 | 1.6 | 900 | 215 | 1360 | 1260×810×1370 | |||||
| 400 | 0.570 | 5.20 | 1.5 | 1080 | 260 | 1650 | 1380×900×1390 | |||||
| 500 | 0.680 | 6.20 | 1.4 | 1250 | 280 | 1890 | 1400×920×1450 | |||||
| 630 | 0.820 | 6.92 | 0.6 | 5.5 | 1470 | 340 | 340 | 1580×1020×1430 | 820/820 | |||
| 800 | 1.000 | 8.46 | 0.6 | 1735 | 385 | 2645 | 1665×1070×1520 | |||||
| 1000 | 1.180 | 9.91 | 0.6 | 1910 | 430 | 2980 | 1740×1160×1550 | |||||
| 1250 | 1.400 | 11.70 | 0.5 | 2210 | 590 | 3640 | 1820×1210×1740 | |||||
| 1600 | 1.680 | 14.10 | 0.4 | 2640 | 680 | 4270 | 1840×1240×1860 | |||||
| 2000 | 2.010 | 16.90 | 0.4 | 2890 | 725 | 4775 | 2210×1920×1970 | |||||
| 2500 | 2.370 | 19.60 | 0.4 | 3460 | 910 | 5710 | 2260×1970×1995 | 1070/1070 | ||||
| 3150 | 2.800 | 23.00 | 0.4 | 4230 | 1350 | 7085 | 2320×2280×2360 | |||||
| 4000 | 10.5 10 |
6.3 3.15 |
3.450 | 27.30 | 0.4 | 5025 | 1675 | 8150 | 2460×2480×2475 | |||
| 5000 | 4.100 | 31.30 | 0.4 | 6020 | 1940 | 9610 | 2575×2640×2590 | |||||
| 6300 | 4.890 | 35.00 | 0.4 | 8125 | 2550 | 12660 | 2640×2820×2810 | |||||
| 8000 | 6.520 | 40.50 | 0.0 | 9620 | 2780 | 15100 | 2710×2840×3040 | 1475/1475 | ||||
| 10000 | 7.700 | 47.70 | 0.6 | 11660 | 3070 | 17480 | 2850×2880×3265 | |||||
Note: ① High voltage tap range: ± 5% or ± 2x2.5%; Frequency 50Hz
The provided external dimensions are for reference only during selection, and the final dimensions are subject to the product's external drawing.
Execution Standards
- GB/T10228, GB/T1094.11, JB/T10088
- GB4208, GB20052
- Rated high voltage: 10 (11, 10.5, 6.6, 6.3, 6) kV
- Connection group number: Dyn11 or Yyn0
- Insulation level: LI75AC35/AC3
- Rated low voltage: 0.4kV
- High voltage tap range: ± 5% or ± 2X2.5%
- Frequency: 50Hz
Normal Condition
- Altitude: not exceeding 1000m
- Maximum environmental temperature: 40 ℃
- Minimum temperature: -25 ℃ (outdoor dry-type transformer)
- Minimum temperature: -5 ℃ (indoor dry-type transformer)
- Maximum monthly average temperature: 30 ℃
- Maximum annual average temperature: 20 ℃
- Relative humidity of the surrounding air: below 93% (no water droplets on the surface of the coil)
- Power supply voltage waveform: approximately a sine wave
- Three-phase power supply voltage: roughly symmetrical (for three-phase transformers)
