China Suppliers Factory FKRN12-12D Indoor High-Voltage Puffer-Type Load Break Switch/Fuse Combination Apparatus

Introducing the FKN12-12 / FKRN12-12D series indoor high-voltage air load break switches and fuse combination electrical apparatus. These advanced devices are designed for three-phase high-voltage switching applications at 12kV and below. As reliable solutions for the control and protection of transformers, cables, overhead lines, and various power equipment, they cater to both urban and rural power distribution networks. Ideal for use in terminal substations, box-type substations, ring main units, and dual power supply systems, these switches ensure efficient unit control and protection. As a leading factory and supplier in China, we are committed to providing high-quality electrical apparatus that meet your power distribution needs

    Overview

    The FKN12-12 / FKRN12-12D series indoor high-voltage air load break switches/fuse combination electrical apparatus are suitable for three-phase high-voltage switching devices of 12kV and below. They are primarily used for the control and protection of transformers, cables, overhead lines, and other power equipment. These devices are especially suitable for urban and rural power distribution networks, terminal substations, and box-type substations. They are also applicable to ring main units and dual power supply systems for unit control and protection.

    Production Features

    Compact Structure, Small Footprint

    Modular design allows easy integration into switchgear panels, saving installation space.

    Puffer-Type Arc Extinguishing Technology

    Utilizes compressed air arc extinguishing for strong breaking capacity and effective arc suppression.

    Integrated Multi-Functionality

    Combines load break switch and fuse, providing disconnection, load breaking, and protection in one unit.

    Fast Fault Interruption

    High-speed fuse clearing ensures quick isolation of fault currents, minimizing equipment damage.

    Visible Isolation Gap

    Provides a clearly visible disconnection point to ensure maintenance safety and meet interlocking requirements.

    Flexible Operation Options

    Supports both manual and motorized operation, suitable for local or remote control.

    Long Mechanical Life, Low Maintenance

    Designed for over 2000 operations with a robust mechanism and reduced service requirements.

    Wide Application Adaptability

    Suitable for urban and rural power networks, compact substations, and ring main units (RMUs).

    Standards Compliance & High Reliability

    Compliant with GB3804, GB16926 and other relevant standards, ensuring high interchangeability and reliability.

    Product Parameter

    No. Item Unit FKN12-12D FKRN12-12D
    1 Rated Voltage kV 12 12
    2 Rated Frequency Hz 50 50
    3 Rated Current A 630 125
    4 Lightning Impulse Withstand Voltage kV Phase to earth 42, across isolating gap 48 Phase to earth 42, across isolating gap 48
    5 1min Power Frequency Withstand Voltage kV Phase to earth 75, across isolating gap 85 Phase to earth 75, across isolating gap 85
    6 Rated Short-Time Withstand Current kA Load break switch: 20; Earthing switch: 20 -
    7 Rated Short-Time Withstand Duration s Load break switch: 4; Earthing switch: 2 -
    8 Rated Peak Withstand Current (Peak) kA 50 -
    9 Rated Breaking Current A Load break switch: 630; Close-open breaking current: 630;
    5% Rated load breaking current: 31.5; Cable charging current: 10
    10 Rated Transformer Breaking Capacity kVA 1250 -
    11 Rated Short-Circuit Breaking Current (Fuse-linked) kA - 31.5
    12 Rated Transfer Current A 1200 -
    13 Mechanical Life times 2000 -
    14 Operating Sequence - 0-0.3s-CO-180s-CO -
    15 Closing Time ms ≤65 -
    16 Opening Time ms ≤10 -

    Frequently Asked Questions

    What are the primary applications for the FKN12-12 series?

    They are designed for 12kV and below three-phase systems, widely used in urban/rural power grids, terminal substations, box-type substations, and ring main units (RMUs) for transformer and cable protection.

    What is the difference between FKN12-12D and FKRN12-12D?

    The FKN12-12D functions primarily as a load break switch, whereas the FKRN12-12D is a switch-fuse combination apparatus that integrates high-speed fuse protection to interrupt short-circuit faults up to 31.5kA.

    How does the puffer-type arc extinguishing technology work?

    It utilizes compressed air generated during the switch operation to extinguish the electrical arc rapidly, ensuring reliable and safe current interruption.

    Does the FKN12-12 support remote operations?

    Yes, it features flexible operation options, supporting both manual control mechanisms and motorized mechanisms for remote system integration.

    What safety mechanisms are built into the switch?

    It includes a clearly visible isolation gap to guarantee maintenance safety, and it complies with GB3804 and GB16926 standards for interlocking requirements.