China Suppliers Factory FLRN36-12D SF6 High Voltage Load Switch for 10kV Power Systems
Overview
Product Features
Efficient Arc - Extinguishing & Insulation
Leverages SF₆ gas for strong arc - quenching and stable insulation, ensuring high - strength fracture port insulation per GB 3906.
Integrated Functionality
Combines closing, opening, and grounding in one compact epoxy - resin - sealed unit, simplifying cabinet layout.
Reliable Interlocking
Mechanical/electrical interlocks prevent misoperations, aligning with DL/T 534 for safe grid operation.
Maintenance - Free Design
Sealed SF₆ system avoids regular refilling, reducing lifecycle costs.
Smart Compatibility
Pairs with intelligent units for “three remotes” (control, signaling, measurement), enabling digital grid integration.
Fast Fault Handling
Rapid fault interruption stabilizes systems, ideal for urban networks/industrial applications per GB/T 11022.
Product Parameters
| No. | Item | Unit | Data |
|---|---|---|---|
| 1 | Rated voltage | KV | 12 |
| 2 | Rated frequency | Hz | 50 |
| 3 | Rated current | A | 630 |
| 4 | Rated peak withstand current | KA | 50 |
| 5 | 4s rated short time withstand current | KA | 20 |
| 6 | Rated making current | KA | 50 |
| 7 | Rated breaking current - Active load breaking current | A | 630 |
| 8 | Rated breaking current - Breaking current loop | A | 630 |
| 9 | Rated breaking current - Cable charging breaking current | A | 10 |
| 10 | 1min power frequency withstand voltage (phase to phase, to earth, fracture) | KV | 42/48 |
| 11 | Lightning impulse withstand voltage (phase to phase, to earth, fracture) | KV | 75/85 |
| 12 | Relative pressure of SF6 gas (20℃ GP) | MPa | ≤0.04 |
| 13 | Rated operating voltage (electric) | V | AC220、DC220 |
| 14 | Rated voltage of shunt release | V | AC220、DC220 |
| 15 | Average opening speed | m/s | 3.5±1.5 |
| 16 | Average closing speed | m/s | 3.5±1.5 |
| 17 | Three - phase points, closing phase of the same | ms | ≤3 |
| 18 | The main circuit resistance | μΩ | ≤120 |
| 19 | Manual maximum torque | N.m | ≤160 |
| 20 | phase to phase center distance | mm | 210±0.5 |
Frequently Asked Questions (FAQ)
What is the primary application of the FLRN36-12D load switch?
It is an indoor switchgear applicable to three-phase AC 10kV, 50Hz power systems, suitable for urban network renovation and industrial and mining enterprises to realize power distribution, control, and protection.
What functions are integrated into this single unit?
The FLRN36-12D integrates three essential functions: closing, opening, and grounding into one compact epoxy resin-sealed unit filled with SF₆ gas.
Why is the FLRN36-12D considered maintenance-free?
Because it features a sealed SF₆ gas system enclosed in an epoxy resin shell, avoiding the need for regular gas refilling and reducing lifecycle maintenance costs.
Does it support smart grid or remote control capabilities?
Yes, it can be adapted to intelligent units to achieve “three remotes” (remote control, remote signaling, and remote measurement), facilitating digital grid integration.
What are the main voltage and current ratings for this switch?
The FLRN36-12D features a rated voltage of 12kV, a rated frequency of 50Hz, a rated current of 630A, a 4s rated short-time withstand current of 20kA, and a rated peak withstand current of 50kA.
What standards does the product comply with regarding insulation and interlocking?
It aligns with GB 3906 for fracture port insulation, DL/T 534 for mechanical/electrical interlocking safety, and GB/T 11022 for fault handling performance.