China Suppliers Factory of Prefabricated Modular Box Type Transformer Substation for Urban Power Grid Renovation

Prefabricated substations, also referred to as modular substations, offer superior flexibility and convenience compared to traditional civil substations. These advanced solutions are increasingly utilized in various settings, including high-rise buildings, residential communities, industrial parks, commercial centers, airports, stations, docks, schools, and mining enterprises. As one of the leading suppliers and factory manufacturers in China, we provide top-quality prefabricated substations designed for urban network renovation and enhanced energy efficiency. Upgrade your infrastructure with our innovative products tailored to meet modern demands

    Overview

    Prefabricated substations (hereinafter referred to as box substations) consist of three parts: high-voltage switchgear, transformers, and low-voltage switchgear. The overall layout includes combination and integrated (commonly known as Euro substations). The so-called combination type refers to the arrangement of these three parts in a "eye" or "cross" shape, each of which is a room. The integrated type is sufficient for the transformer to be the main body, and the high-voltage load switch and fuse are installed inside the transformer box to form an integrated arrangement.

    Model and Meaning

    Prefabricated Box Type Transformer Substation (European Style) Model Diagram

    Environmental Conditions for Use

    • ✓ Altitude not exceeding 4000m;
    • ✓ Environmental temperature: -25 ℃ -40 ℃;
    • ✓ Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;
    • ✓ Installation location: A place without fire, explosion hazards, conductive dust, corrosive chemical gases, and severe vibrations. If the above conditions are exceeded, users can negotiate with our company.

    Function and Characteristic

    • 1. High voltage switchgear, transformers, and low voltage switchgear are integrated into one, with strong completeness;
    • 2. Complete high and low voltage protection, safe and reliable operation, and simple maintenance;
    • 3. Small land occupation, low investment, short production cycle, and convenient mobility;
    • 4. The grounding scheme is flexible and diverse;
    • 5. Unique structure: The unique honeycomb structure double-layer (composite board) shell is firm, insulated, ventilated, beautiful, and has a high level of protection. The shell materials include stainless steel alloy, aluminum alloy, cold-rolled plate, color steel plate, and ceramic tile. Wooden strips, new environmentally friendly materials, and surface watercolor paintings are optional;
    • 6. Diverse types: universal, villa, compact, and various styles;
    • 7. The high-voltage ring main unit can be equipped with a network automation terminal (FTU) to achieve reliable detection of short circuits and single-phase grounding faults. It has the "four remote" function, which facilitates the upgrade of distribution network automation. This series is widely used in urban power grid renovation, residential communities, high-rise buildings, industrial and mining areas, hotels, shopping malls, airports, railways, oil fields, docks, highways, as well as temporary power facilities and other indoor and outdoor places.

    Product Introduction

    ◆ Overall structure

    a. Modular Transport

    The product is mainly divided into three parts: high-voltage switchgear room, transformer room, and low-voltage switchgear room, which can be transported separately.

    b. Heat Dissipation

    The product adopts a unique large circulation heat dissipation design to ensure the temperature rise level of the product, and the separate sealing between each chamber will not form heat exchange between each chamber.

    c. Anti-corrosion Shell

    The product shell is made of high-quality stainless steel plate. The various components of the steel plate structure have undergone special anti-corrosion treatment, and the stainless steel plate structure has extremely strong corrosion resistance and good mechanical strength.

    d. Easy Installation

    The product can be directly installed indoors without the need for additional building foundations, saving costs and space, and making installation convenient.

    ◆ High voltage chamber

    The high voltage adopts our company's independently developed SF6 gas filled switchgear, which seals all switchgear, busbars, etc. in a sealed stainless steel box without exposed live parts on the outside. Safe operation and high reliability; Fully modular design, all modules can be connected with side outlets and top extensions according to power requirements, maximizing the satisfaction of power supply solutions.

    ◆ Low voltage chamber

    The low-voltage side incoming and outgoing lines are all equipped with new plastic shell circuit breakers, which have small switch volume, no arcing, and are easy to replace; Multi functional intelligent comprehensive protection controller and new integrated reactive power compensation device.

    ◆ Transformer Room

    The transformer adopts epoxy resin fully insulated transformer with insulation and heat resistance level of F. The transformer has no combustion supporting materials and does not produce any gases or other intermediate products that are harmful to the environment during operation. It has good flame retardant, environmental protection, energy-saving and other characteristics.

    ◆ Internal connection

    The transformer is connected to the Chinese solid switch using our company's solid insulated cable accessories, which are safe, reliable, and fully insulated.

    Performance Parameter

    Item Unit Parameter
    High - Voltage Unit Rated frequency Hz 50
    Rated voltage kV 6, 10, 35
    Maximum operating voltage kV 6.9, 11.5, 40.5
    Rated current A 400, 630, 1250
    Transfer current A 1200 - 3150
    Power - frequency withstand voltage (to ground and phase - to - phase / isolation break) kV 42/48
    Lightning impulse withstand voltage (to ground and phase - to - phase / isolation break) kV 75/85
    Rated short - circuit breaking current (current - limiting fuse) kA 31.5
    Transformer Unit Rated voltage kV 6, 10, 35
    Rated capacity kVA 30 - 2000
    Tap range % ±2×2.5%, ±5%
    Connection group Yyn0, Dyn11
    Impedance voltage % 4, 4.5, 6, 8
    Low - Voltage Unit Rated voltage V 220, 380, 690, 800
    Rated current of main circuit A 50 - 4000
    Branch current A 5-800
    Enclosure Protection level (conventional products) High - voltage room IP33; Transformer room IP23; Low - voltage room IP33
    Noise level dB ≤50

    Frequently Asked Questions (FAQ)

    What are the main components of a prefabricated substation?
    A prefabricated substation consists of three main parts: high-voltage switchgear, a transformer, and low-voltage switchgear. These can be arranged in a combined layout (commonly known as a European substation) or in an integrated layout.
    What environmental conditions are suitable for this substation?
    It is designed for altitudes not exceeding 4000m, environmental temperatures between -25 ℃ and 40 ℃, and relative humidity not exceeding 95% (daily average). The installation site should be free from fire, explosion hazards, conductive dust, and severe vibrations.
    What materials are used for the outer shell of the substation?
    The substation features a unique honeycomb structure double-layer composite shell. Customers can choose from stainless steel alloy, aluminum alloy, cold-rolled plate, color steel plate, ceramic tile, wooden strips, or new eco-friendly materials.
    Does the substation support distribution network automation?
    Yes. The high-voltage ring main unit can be equipped with a network automation terminal (FTU) to detect short circuits and single-phase grounding faults, enabling the "four remote" function for smooth automation upgrades.
    What are the benefits of the transformer used in this substation?
    It features an epoxy resin fully insulated transformer with a Class F insulation and heat resistance rating. It is flame retardant, energy-saving, contains no combustion-supporting materials, and releases no harmful gases during operation.