0102030405
China ZW32-12 Outdoor Medium Voltage Vacuum Circuit Breaker - Reliable Suppliers & Factory for Power Distribution Solutions
Overview
ZW32-12 outdoor high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is outdoor distribution equipment with rated voltage of 12kV and three-phase AC of 50Hz. It is mainly used to open and close load current, overload current and short circuit current in power system. It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume, lightweight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and a dirty environments.
Model and Meaning
Working Conditions
- 🔹 Environment Temperature: Upper limit +40°C, lower limit -30°C
- 🔹 Altitude: ≤ 2000 meters
- 🔹 Wind Pressure: ≤ 700Pa (corresponding to wind speed 34m/s)
- 🔹 Earthquake Intensity: Do not exceed 8 degrees
- 🔹 Pollution Grade: Class I
- 🔹 Maximum Daily Temperature: Less than 25°C
Technical Parameters
| Name | Unit | Data | ||
|---|---|---|---|---|
| Rated Voltage | kV | 12 | ||
| Rated Insulation Level | 1min Power Frequency Withstand Voltage | Dry Test (To Ground, Pole-to-Pole / Break) | kV | 42/48 |
| Wet Test | kV | 34 | ||
| Lightning Impulse Withstand Voltage (Peak Value, Pole-to-Pole / Break) | kV | 75/85 | ||
| Rated Current | A | 630 | ||
| Rated Short-Circuit Breaking Current | kA | 20 | ||
| Rated Operating Sequence | - | O~0.3-CO-180S-COS | ||
| Rated Short-Circuit Breaking Current Breaking Times | Times | 30 | ||
| Rated Short-Circuit Making Current (Peak Value) | kA | 50 | ||
| Rated Peak Withstand Current | ||||
| Rated Short-Time Withstand Current | 20 | |||
| Rated Short-Circuit Duration Time | S | 4 | ||
| Opening Time | ms | ≤35 | ||
| Closing Time | ms | ≤40 | ||
| Mechanical Life | Times | 10000 | ||
| Rated Closing Operation Voltage | V | DC110 | ||
| Rated Opening Operation Voltage | ||||
| Overcurrent Protection | Current Setting Multiple | - | 0.2~2.5 | |
| Allowable Deviation of Setting Current | - | ±10% | ||
| Delay Setting Value | S | 0~5 | ||
| Delay Tolerance | - | ±10% | ||
| Instantaneous Trip Protection | Current Setting Multiple | - | 2.5~10 | |
| Allowable Deviation of Setting Current | - | ±10% | ||
| Delay Setting Value | S | 0~0.5 | ||
| Delay Tolerance | - | ±10% | ||
| AC Charging Input Current of Control Unit | Rated Value | A | 5 | |
| Fluctuation Range | 0.5~8 | |||
Product Size Description
Frequently Asked Questions (FAQ)
Q1: What is the rated voltage and frequency of the ZW32-12 circuit breaker?
The ZW32-12 outdoor high voltage vacuum circuit breaker is designed for distribution systems with a rated voltage of 12kV and a three-phase AC frequency of 50Hz.
Q2: What are the primary applications for this outdoor vacuum circuit breaker?
It is mainly used to open and close load current, overload current, and short circuit current. It is highly suitable for substation protection, industrial and mining enterprises, and frequently operated rural power grids.
Q3: What environmental working conditions can the ZW32-12 withstand?
It operates reliably in temperatures ranging from -30°C to +40°C, at altitudes up to 2000 meters, under wind pressures up to 700Pa, and in areas with earthquake intensities up to 8 degrees.
Q4: Does the ZW32-12 require frequent maintenance?
No, one of its main characteristics is that it is free of maintenance. It features anti-condensation properties and a small volume, allowing it to adapt easily to harsh weather and dirty environments.
Q5: What is the mechanical life expectancy of this circuit breaker?
The ZW32-12 outdoor high voltage vacuum circuit breaker has a mechanical life rating of 10,000 operations.