CKSG Low Voltage Three-Phase Reactor from China Suppliers – Quality Factory for Power Quality Improvement
Overview
The CKSG low-voltage three-phase reactor is a supporting device for low-voltage reactive power compensation installations. It is suitable for AC 50Hz power systems with a rated voltage of 6 - 35kV (common low-voltage ratings include 0.4kV, etc.). When connected in series with low-voltage capacitors, it can suppress harmonic currents, inrush currents during switching, and operating overvoltages, preventing damage to capacitors and a reduction in the power factor. Additionally, it can absorb harmonics, improve power quality, facilitate the stable operation of the system, and extend the service life of capacitors. It mostly adopts a dry-type iron-core structure, and processes such as vacuum pressure impregnation are used to ensure performance.
Product Features
1. Harmonic & Inrush Suppression
Suppresses harmonic currents (THDi ≤ 10% per GB/T 14549) and inrush currents during capacitor switching, preventing insulation breakdown of capacitors.
Mitigates switching overvoltages to maintain power factor stability (≥0.95) in low-voltage systems.
2. Power Quality Optimization
Absorbs dominant harmonics (5th, 7th, etc.) to reduce voltage total harmonic distortion (THDu ≤ 5%).
Stabilizes bus voltage fluctuations, ensuring compliance with GB/T 12325 for voltage quality.
3. Dry-Type Core Structure
Adopts laminated silicon steel core with low eddy current loss (≤0.3W/kg at 1.7T, 50Hz).
Vacuum Pressure Impregnation (VPI) process enhances insulation strength (dielectric withstand voltage ≥3kV) and moisture resistance (IP20 protection).
4. System Synergy
Forms LC filtering loops with BSMJ-series capacitors, reducing reactive power loss by 30-40%.
Supports stepwise compensation configurations (10-500kvar) for scalable reactive power control.
5. Reliability & Longevity
Temperature rise ≤65K under rated load, ensuring continuous operation at -25℃~+45℃.
Built-in thermal protection triggers alarm at core temperature >130℃ (Class B insulation).
6. Installation Flexibility
Vertical/horizontal mounting compatible with standard low-voltage switchgear (e.g., GGD, GCK cabinets).
Low noise design (≤55dB at 1m) suitable for indoor power distribution rooms.
7. Compliance with Standards
Meets JB/T 9644 (dry-type reactor technical specifications) and IEC 60289 for reactor performance.
Product Parameters
| Reactor model | Matching capacitor capacity (kvar) | Reactor capacity | Inductance (mH) | Insulation class | Dimensions D*W*H (mm) | Installation size (mm) |
|---|---|---|---|---|---|---|
| CKSG-0.35/0.45-7% | 5 | 0.35 | 9 | F、H | 170*100*160 | 150*60 |
| CKSG-0.7/0.45-7% | 10 | 0.7 | 4.5 | F、H | 175*110*160 | 150*70 |
| CKSG-1.05/0.45-7% | 15 | 1.05 | 3 | F、H | 175*145*160 | 150*80 |
| CKSG-1.4/0.45-7% | 20 | 1.4 | 2.3 | F、H | 200*155*185 | 170*80 |
| CKSG-1.75/0.45-7% | 25 | 1.75 | 1.8 | F、H | 240*165*210 | 200*90 |
| CKSG-2.1/0.45-7% | 30 | 2.1 | 1.5 | F、H | 240*170*210 | 200*95 |
| CKSG-2.45/0.45-7% | 35 | 2.45 | 1.3 | F、H | 240*175*210 | 200*100 |
| CKSG-2.8/0.45-7% | 40 | 2.8 | 1.1 | F、H | 240*180*210 | 210*105 |
| CKSG-3.15/0.45-7% | 45 | 3.15 | 1 | F、H | 240*190*210 | 200*110 |
| CKSG-3.5/0.45-7% | 50 | 3.5 | 0.9 | F、H | 250*190*210 | 210*110 |
| CKSG-4.2/0.45-7% | 60 | 4.2 | 0.75 | F、H | 250*190*250 | 210*120 |
| CKSG-1.4/0.525-14% | 10 | 1.4 | 12.3 | F、H | 200*120*190 | 170*80 |
| CKSG-2.1/0.525-14% | 15 | 2.1 | 8.2 | F、H | 240*165*210 | 200*95 |
| CKSG-2.8/0.525-14% | 20 | 2.8 | 6.1 | F、H | 240*175*210 | 200*105 |
| CKSG-3.5/0.525-14% | 25 | 3.5 | 4.9 | F、H | 240*185*240 | 200*110 |
| CKSG-4.2/0.525-14% | 30 | 4.2 | 4.1 | F、H | 250*185*250 | 210*110 |
| CKSG-5.6/0.525-14% | 40 | 5.6 | 3.1 | F、H | 250*190*265 | 210*115 |
| CKSG-7.0/0.525-14% | 50 | 7 | 2.5 | F、H | 310*200*285 | 260*120 |
| Reactor model | Matching capacitor capacity (kvar) | Reactor capacity (kvar) | Inductance (mH) | Dimensions D*W*H (mm) | Installation size (mm) |
|---|---|---|---|---|---|
| CKDG-0.35/0.25-7% | 5 | 0.35 | 2.8 | 135*155*140 | 95×105.4-φ8 |
| CKDG-0.525/0.25-7% | 7.5 | 0.525 | 1.9 | 135*165*155 | 95×105.4-φ8 |
| CKDG-0.7/0.25-7% | 10 | 0.7 | 1.4 | 170*175*160 | 120×115.4-φ8 |
| CKDG-1.05/0.25-7% | 15 | 1.05 | 0.93 | 170*195*180 | 120×135.4-φ8 |
| CKDG-1.4/0.25-7% | 20 | 1.4 | 0.7 | 155*195*210 | 105×135.4-φ8 |
| CKDG-1.75/0.25-7% | 25 | 1.75 | 0.56 | 155*205*210 | 105×145.4-φ8 |
Frequently Asked Questions
The CKSG low-voltage reactor is designed to connect in series with low-voltage capacitors in reactive power compensation systems. It suppresses harmonic currents, switching inrush currents, and operating overvoltages to prevent capacitor damage and maintain the system's power factor stability.
The Vacuum Pressure Impregnation (VPI) process enhances the reactor's insulation strength (providing a dielectric withstand voltage of ≥3kV) and improves moisture resistance to achieve an IP20 protection rating.
It adopts a dry-type iron-core structure utilizing laminated silicon steel cores, which ensures low eddy current loss of ≤0.3W/kg at 1.7T, 50Hz.
Yes, it features built-in thermal protection (Class B insulation) that triggers an alarm when the core temperature exceeds 130°C, ensuring safe operation within its rated environment of -25°C to +45°C.
The reactors are compliant with JB/T 9644 dry-type reactor technical specifications and the IEC 60289 international standard for reactor performance.