FLRN36-12D SF6 HV Load Switch
Overview
The FLRN36 - 12D SF₆ high - voltage load switch is an indoor switchgear applicable to three - phase AC 10kV, 50Hz power systems. It uses SF₆ gas as the arc - extinguishing and insulating medium, integrating three functions of closing, opening, and grounding into one unit, and is sealed in an epoxy resin shell filled with SF₆ gas, featuring a compact structure. It has characteristics such as reliable interlocking, high insulation strength of fracture ports, and maintenance - free operation. It can be matched with complete sets of power distribution equipment, ring - main switch cabinets, etc., and is used in scenarios like urban network renovation and industrial and mining enterprises to realize power distribution, control, and protection. Moreover, it can be adapted to intelligent units to achieve “three remotes” (remote control, remote signaling, remote measurement). It has a fast fault - breaking speed, which is beneficial for system stability.
Product Features
Efficient Arc - Extinguishing & Insulation:Leverages SF₆ gas for strong arc - quenching and stable insulation, ensuring high - strength fracture port insulation per GB 3906.
Integrated Functionality:Combines closing, opening, and grounding in one compact epoxy - resin - sealed unit, simplifying cabinet layout.
Reliable Interlocking:Mechanical/electrical interlocks prevent misoperations, aligning with DL/T 534 for safe grid operation.
Maintenance - Free Design:Sealed SF₆ system avoids regular refilling, reducing lifecycle costs.
Smart Compatibility:Pairs with intelligent units for “three remotes” (control, signaling, measurement), enabling digital grid integration.
Fast Fault Handling:Rapid fault interruption stabilizes systems, ideal for urban networks/industrial applications per GB/T 11022.
Product Parameters
| No. | Item | Unit | Data |
| 1 | Rated voltage | KV | 12 |
| 2 | Rated frequency | Hz | 50 |
| 3 | Rated current | A | 630 |
| 4 | Rated peak withstand current | KA | 50 |
| 5 | 4s rated short time withstand current | KA | 20 |
| 6 | Rated making current | KA | 50 |
| 7 | Rated breaking current - Active load breaking current | A | 630 |
| Rated breaking current - Breaking current loop | A | 630 | |
| Rated breaking current - Cable charging breaking current | A | 10 | |
| 8 | 1min power frequency withstand voltage (phase to phase, to earth, fracture) | KV | 42/48 |
| 9 | Lightning impulse withstand voltage (phase to phase, to earth, fracture) | KV | 75/85 |
| 10 | Relative pressure of SF6 gas (20℃ GP) | MPa | ≤0.04 |
| 11 | Rated operating voltage (electric) | V | AC220、DC220 |
| 12 | Rated voltage of shunt release | V | AC220、DC220 |
| 13 | Average opening speed | m/s | 3.5±1.5 |
| 14 | Average closing speed | m/s | 3.5±1.5 |
| 15 | Three - phase points, closing phase of the same | ms | ≤3 |
| 16 | The main circuit resistance | μΩ | ≤120 |
| 17 | Manual maximum torque | N.m | ≤160 |
| 18 | phase to phase center distance | mm | 210±0.5 |