Leave Your Message
Products Categories
Featured Products

GGJ Low Voltage Capacitor Bank - China Suppliers & Factory for Power Distribution and Reactive Power Compensation

Introducing the GGJ series low voltage capacitor bank, specifically engineered for power distribution systems operating at 220-690V and frequencies of 50/60Hz. This advanced equipment excels in reactive power compensation through the automatic switching of capacitor banks. With its innovative design and superior technology, the GGJ series is an essential solution for low voltage power grids in China. It significantly enhances power factor, minimizes reactive power loss, and improves overall power supply quality. As a leading factory among suppliers, we proudly present this cutting-edge power-saving product to meet your energy efficiency needs

    Overview

    GGJ series low voltage capacitor bank is specially designed for power distribution system with voltage of 220-690V and frequency of 50/60Hz. It performs reactive power compensation by automatically switching capacitor banks. It has reasonable structure and advanced technology. It is widely used in low voltage power grids to improve power factor, reduce reactive power loss and improve power supply quality. It is a new generation of power saving products.

    Normal Operating Conditions

    Altitude: ≤ 2000m
    Ambient temperature: -20°C ~ +45°C
    Relative humidity: ≤ 90% at 20°C
    Installation environment: No harmful gases, vapors, non-conductive or explosive dust, and severe (mildew).

    Main Technical Parameters

    Rated voltage: 0.38 - 0.66kV
    Rated frequency: 50Hz
    Rated capacity: 1 - 600kvar
    Applicable voltage range: (0.85 - 1.1) times the rated voltage
    Maximum allowable current: 1.3 times the rated current
    Control circuits: 1 - 16 circuits
    Switching time: 1 - 150S/time, adjustable
    Working mode: Automatic, continuous operation

    Main Features

    • Controlled by an intelligent controller, with complete functions, reliable performance, and automatic compensation mode: Can increase the power factor to above 0.9.
    • Real-time display of grid power factor, display range: Lag (0.00 - 0.99), lead (0.00 - 0.99).
    • With multiple comprehensive protection functions such as over-voltage, harmonic, over-compensation, system fault, phase loss, and over-load.
    • Memory of set parameters, no parameter loss after system power failure, automatic entry into operation state after grid recovery, no need for personnel on duty.
    • Can adopt phase-splitting compensation or mixed compensation according to the grid load balance status.
    • Strong anti-interference ability, can withstand 2000V interference pulses input from the grid, higher than national professional standards.
    • Energy saving: Effectively compensates for reactive power, significantly reducing line losses and power system-related operating costs.
    • System stability: By improving the power factor, the overall stability and reliability of the power supply system are enhanced.
    • Fast capacitor switching: With fast and precise capacitor switching capabilities, it can effectively meet the needs of the power grid.

    Product Parameters

    Item Units Value
    Rated Voltage V 220/400/690
    Rated Frequency Hz 50/60
    Applicable Voltage Range - 0.85-1.1 times the rated voltage
    Maximum Permissible Current - 1.3 times the rated Current
    Control Loop Quantity - 1-16 loops
    Working Mode - automatic and continuous working

    Frequently Asked Questions (FAQ)

    What is the primary function of the GGJ series low voltage capacitor bank?
    The GGJ series low voltage capacitor bank is designed for power distribution systems (220-690V, 50/60Hz) to perform automatic reactive power compensation. It helps improve power factor, reduce reactive power loss, and enhance overall power supply quality.
    What are the environmental requirements for installing the GGJ capacitor bank?
    It requires an altitude of ≤ 2000m, ambient temperatures between -20°C and +45°C, and relative humidity ≤ 90% (at 20°C). The installation site must be free from harmful gases, vapors, non-conductive or explosive dust, and severe mildew.
    What safety and protection features does the system include?
    The device is equipped with multiple protection functions, including over-voltage, harmonic, over-compensation, system fault, phase loss, and over-load protections.
    Does the system lose its parameters during a power failure?
    No, it features a parameter memory function. There is no parameter loss after a power failure, and the system automatically returns to normal operation once power is restored.
    How does the GGJ series achieve energy savings?
    By effectively compensating for reactive power and increasing the power factor above 0.9, it reduces line losses and lowers operating costs related to the power system.

    Leave Your Message