GN19-12 Indoor High Voltage Isolation Switch
Overview
GN19-12 series indoor high-voltage isolation relationship high-voltage switchgear is used in power systems with rated voltage of 12KV, AC 50Hz and below. It is equipped with CS6-1 manual operating mechanism and is used for opening and closing circuits under voltage and no load. It also has derivative products such as anti fouling type, high-altitude type, and equipped with live display devices.
The isolation switch in this department is equipped with the CS6-1 manual operating mechanism.
This series of isolating switches is a three pole type, consisting of a chassis, a shaft, a lever, a porcelain pillar insulator, a switch blade, and a terminal block. The rotating shaft is mounted on the chassis and has three pairs of levers welded on it. The levers are connected to a ceramic insulator and a knife chain through a pull rod. The rotating shaft extends out of the chassis, and any section of it can be connected to the operating mechanism.
Type C is a through wall type. Where C1 represents rotation on the through wall side; C2 represents the disconnection on the through wall side;C3 indicates that both sides are on the through wall side.
Model and meaning

Environmental condition of use
Altitude not exceeding 1000m;
Surrounding air temperature: -25 ℃~+40 ℃;
The seismic intensity shall not exceed 8 degrees;
Relative humidity of the surrounding environment: daily average not exceeding 95%, monthly average not exceeding 90%;
Installation location: No fire, flammable, explosive, severely polluted, chemically corroded, or violently vibrating areas.
Technical parameter
|
Item |
Unit |
Parameter |
||||||||
|
Rated Voltage |
KV |
12 |
||||||||
|
1min Power Frequency Withstand Voltage |
To ground |
KV |
42 |
|||||||
|
Break |
KV |
48 |
||||||||
|
Lightning Impulse Withstand Voltage (Peak Value) |
To Ground |
KV |
75 |
|||||||
|
Break |
KV |
85 |
||||||||
|
Rated Frequency |
HZ |
50 |
||||||||
|
Rated Current |
A |
400 |
630 |
1000 1250 |
||||||
|
Rated Short - time Withstand Current |
KA |
16 |
20 |
16 |
20 |
25 |
20 |
25 |
31.5 |
|
|
Rated Peak Withstand Current |
KA |
40 |
50 |
40 |
50 |
63 |
50 |
63 |
80 |
|
|
Duration of Rated Short - time Withstand Current Main Switch/Earthing Switch |
s |
4/2 |
||||||||
|
Creepage Distance |
mm |
300 - 380 |
||||||||
|
Mechanical Life |
Times |
2000 |
||||||||
Appearance and installation size

Product type
| Product type | A | B | C | D | E | F | ||||||
| GN19-12/400 | 450 | 436 | 4-14x24 | 210 | 230 | 250 | 620 | 660 | 700 | 870 | 900 | 940 |
| GN19-12/630 | 490 | 436 | ||||||||||
| 510 | 530 | 4-18x28 | ||||||||||
| GN19-12C/400 | 420 | 625 | 4-14x24 | |||||||||
| GN19-12C/630 | 460 | 625 | ||||||||||
| 505 | 745 | 4-18x28 | ||||||||||