Our company's products use Dyn11 in the connection group, which can significantly reduce the adverse effects of harmonics on the power grid and improve the quality of power supply. Its fully sealed structure is a major highlight. It eliminates the oil storage tank and automatically adjusts the oil volume change through the elasticity of the corrugated oil tank's corrugated sheet, isolating the transformer from air and effectively preventing and slowing down oil degradation and insulation aging, extending its service life. During normal operation, there is no need to hang the core or repair it. In addition, the transformer has excellent short-circuit resistance design, such as using low axial short-circuit force structure coils and high reliability support structure body, greatly improving the ability to withstand short circuits.
Technical Parameters
| Rated Capacity kVA | Voltage Combination kV | Connection Symbol | Loss kW | No-load Current % | Short-circuit Impedance % | Weight kg | External dimensions(mm) L*B*H | Track gauge | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| High Voltage | Low Voltage | No-load | Load | Equipment Weight | Oil Weight | Total Weight | ||||||
| 200 | 10.5 10 6.3 6 |
6.3 3.1 5 3 |
Yd11 Dy11 |
0.34 | 3.15 | 1.8 | 4.5 | 650 | 160 | 1000 | 1180×740×1270 | 660/660 |
| 250 | 0.40 | 3.6 | 1.7 | 770 | 200 | 1190 | 1230×800×1340 | |||||
| 315 | 0.48 | 4.3 | 1.6 | 900 | 215 | 1300 | 1320×810×1370 | |||||
| 400 | 0.57 | 5.2 | 1.5 | 1080 | 260 | 1650 | 1380×900×1390 | |||||
| 500 | 0.68 | 6.2 | 1.4 | 1250 | 280 | 1890 | 1400×920×1450 | |||||
| 630 | 0.82 | 6.92 | 0.6 | 5.5 | 1470 | 340 | 2245 | 1580×1020×1430 | 820/820 | |||
| 800 | 1.00 | 8.96 | 0.6 | 1735 | 385 | 2685 | 1665×1070×1520 | |||||
| 1000 | 1.18 | 9.91 | 0.6 | 1910 | 430 | 2940 | 1740×1160×1550 | |||||
| 1250 | 1.40 | 11.7 | 0.5 | 2210 | 590 | 3640 | 1820×1210×1740 | |||||
| 1600 | 1.68 | 14.1 | 0.4 | 2640 | 680 | 4270 | 1940×1240×1860 | |||||
| 2000 | 2.01 | 16.9 | 0.4 | 2890 | 725 | 4775 | 2210×1920×1970 | |||||
| 2500 | 2.37 | 19.6 | 0.4 | 3460 | 910 | 5710 | 2260×1970×1995 | 1070/1070 | ||||
| 3150 | 2.80 | 23.3 | 0.4 | 4230 | 1350 | 7085 | 2320×2280×2360 | |||||
| 4000 | 10.5 | 6.3 3.1 5 |
3.45 | 27.3 | 0.4 | 5025 | 1675 | 8150 | 2640×2480×2475 | |||
| 5000 | 4.10 | 31.3 | 0.4 | 6020 | 1940 | 9610 | 2575×2640×2590 | |||||
| 6300 | 4.89 | 35 | 0.4 | 8125 | 2550 | 12660 | 2640×2820×2810 | |||||
| 8000 | 6.52 | 40.5 | 0 | 9620 | 2780 | 15100 | 2710×2840×3040 | 1475/1475 | ||||
| 10000 | 7.70 | 47.70 | 0.55 | 11660 | 3070 | 17480 | 2850×2880×3265 | |||||
Note: ① High voltage tap range: * 5% or * 2 * 2.5%; Frequency 50Hz
The provided external dimensions are for reference only during selection, and the final dimensions are subject to the product's external drawing
Normal Use Conditions
Altitude: Not exceeding 1000m
Environmental Temperature: Maximum temperature +40 ℃
Hottest Month Average: The average temperature of the hottest month is +30 ℃
Annual Average Temp: The highest annual average temperature is +20 ℃
Minimum Temperature: The minimum outdoor temperature is -25 ℃
Voltage Waveform: Approximately a sine wave
Symmetry: For three-phase transformers, the three-phase power supply voltage should be roughly symmetrical
Installation Environment: There is no obvious pollution in the installation environment
Earthquake Acceleration: Horizontal direction less than 3m/s², vertical direction less than 1.5m/s²
Special Usage Conditions
Any special usage conditions beyond the normal usage conditions of the transformer should be specified during the inquiry and ordering process.
Execution Standards
The transformer products produced by our company meet the latest version of the above standards.
Ordering Instructions
When placing an order, the product model, rated capacity, high and low voltage ratings, high voltage division range, number of phases, frequency, and connection group number should be provided.
Frequently Asked Questions
QWhat are the benefits of using the Dyn11 connection group in your transformers?
Using the Dyn11 connection group significantly reduces the adverse effects of harmonics on the power grid, which helps to improve the overall quality of the power supply.
QHow does the fully sealed structure extend the transformer's service life?
The fully sealed structure eliminates the oil storage tank. It automatically adjusts oil volume changes through the elasticity of the corrugated sheets, isolating the oil from the air. This prevents and slows down oil degradation and insulation aging, meaning no core hanging or maintenance is required during normal operation.
QWhat design features improve the transformer's short-circuit resistance?
The transformer utilizes a low axial short-circuit force structure for the coils and a high-reliability support structure body, which greatly enhances its ability to withstand short circuits.
QWhat are the standard environmental requirements for operating these transformers?
They should be installed in environments with no obvious pollution, at an altitude not exceeding 1000m, with outdoor temperatures ranging between -25 °C and +40 °C, and within specific seismic ground acceleration limits (horizontal < 3m/s², vertical < 1.5m/s²).
QWhat details must be provided when placing an order?
When ordering, you need to provide the product model, rated capacity, high and low voltage ratings, high voltage division range, number of phases, frequency, and the connection group number.