Intelligent Universal Air Circuit Breaker (ACB) - Low-Voltage Solutions from China Suppliers & Factory
Overview
W1 air circuit breaker is a universal low-voltage circuit breaker, suitable for distribution networks with AC 50Hz, rated voltage up to 660V (690V) and below, and rated current of 400A ~ 6300A. Its main function is to distribute electric energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding and other fault hazards. It is widely used in power distribution of industrial and mining enterprises, low-voltage side of power plants and substations, and power distribution systems of commercial buildings.
Core Technical Features
(I) Protection Functions
- The intelligent release enables long-time delayed inverse-time over-load protection.
- Short-time delayed inverse-time/timed short-circuit protection.
- Instantaneous short-circuit protection and single-phase ground protection.
- Accurately responds to different faults, quickly breaks the circuit, minimizes power outage range, and prevents electrical hazards.
(II) Structural Design
- Contact System: Adopts a multi-contact parallel structure + insulated small chamber + arc-extinguishing system, improving breaking speed and capacity, achieving a high breaking capacity (80 - 100kA).
- Operating Mechanism: Spring-energy-storage mechanism, supporting electric/manual energy storage, closing and opening. Fast closing suppresses inrush current during closing.
- Types: Available in draw-out type (three-position interchangeable) and fixed type (simple structure, low cost).
(III) Intelligent Control & Expansion
- Intelligent releases are classified into electronic, standard, and communication types.
- The communication type supports "four-remote" (remote measurement, remote signal, remote control, remote adjustment) docking with intelligent systems.
- Optional functions include voltage display, load monitoring, disconnection diagnosis, and harmonic monitoring, meeting the needs of refined management.
Product Parameters
| Parameter Category | Parameter | Technical Specifications | Explanation/Basis |
|---|---|---|---|
| Basic Electrical Parameters | Rated Working Voltage (Ue) | AC 400V, 690V (common), up to 1000V | Suitable for low-voltage distribution systems |
| Rated Current (In) | 400A to 6300A (various models) | Covers different power distribution capacities | |
| Rated Short-Circuit Breaking Capacity (Icu) | 35kA, 50kA, 65kA, 80kA, 100kA (RMS) | Indicates fault interruption capability | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | Typically 50%, 75%, or 100% of Icu (e.g., Ics = Icu) | Reflects repeated fault interruption capability | |
| Rated Short-Time Withstand Current (Icw) | 20kA, 30kA, 40kA (withstand for 4s) | Thermal withstand capability for short circuits | |
| Protection Function Parameters | Overload Long-Time Delay Protection (Ir1) | (0.4–1)In continuously adjustable, inverse-time characteristic | Follows IEC 60947-2 standard curves |
| Short-Circuit Short-Time Delay Protection (Ir2) | (2–10)In continuously adjustable, timed/inverse-time selectable | Enables selective tripping with upstream/downstream protection | |
| Short-Circuit Instantaneous Protection (Im) | (5–20)In continuously adjustable (fixed multiples in some models) | Rapid interruption of severe short circuits | |
| Single-Phase Ground Fault Protection | Ground fault current threshold (e.g., 0.2In–1In adjustable) | Requires zero-sequence current transformer | |
| Mechanical & Structural Parameters | Operating Mechanism Type | Spring energy-storage mechanism (electric/manual energy storage) | Electric for automation, manual for debugging |
| Mounting Type | Draw-out type, fixed type | Draw-out type supports three positions (connect/test/disconnect) | |
| Pole Number | 3P, 4P | Suitable for 3-phase 3-wire/4-wire systems | |
| Arcing Distance | 0mm (zero arcing design) | Enables compact installation without arc spraying | |
| Environmental & Adaptation Parameters | Ambient Temperature | -5°C–+40°C (24h average ≤35°C); extended to -40°C–+70°C for some derivatives | Complies with GB 14048.2 standard |
| Altitude | ≤2000m (insulation level must be upgraded for higher altitudes) | Special design required for high altitudes | |
| Protection Level | IP30 (IP40/IP54 optional after cabinet installation) | Dust and foreign object protection | |
| Intelligent Control Parameters | Release Type | Electronic type, intelligent type (M/H/L models) | Intelligent models support communication and parameter display |
| Communication Interface | RS485 (supports Modbus, Profibus, etc.) | Enables "Four Remotes" (remote measurement/signal/control/adjustment) | |
| Other Parameters | Mechanical Life | 20,000–30,000 operations (closing/opening) | Impacts long-term reliability |
| Control Power Supply Voltage | AC220V, DC220V, AC380V, etc. | Must match system control power supply |
Frequently Asked Questions
1. What is the rated current range of the W1 Air Circuit Breaker?
The W1 Air Circuit Breaker covers a wide range of rated currents from 400A to 6300A, making it suitable for various low-voltage power distribution capacities.
2. What protection functions does the intelligent release offer?
The intelligent release provides comprehensive protection, including long-time delayed inverse-time overload protection, short-time delayed inverse-time/timed short-circuit protection, instantaneous short-circuit protection, and single-phase ground protection.
3. What is the difference between the draw-out type and fixed type?
The draw-out type features a three-position design (connect, test, disconnect) with interchangeable components for easy maintenance and replacement. The fixed type offers a simpler, more compact structure with lower installation costs.
4. Does the W1 circuit breaker support remote control and smart grids?
Yes, the communication-type intelligent release supports an RS485 interface with protocols like Modbus and Profibus. This enables "four-remote" functions: remote measurement, remote signal, remote control, and remote adjustment.
5. What is the breaking capacity of the W1 circuit breaker?
Due to its advanced contact system with a multi-contact parallel structure and integrated arc-extinguishing system, the W1 circuit breaker achieves a high breaking capacity ranging from 80kA to 100kA.
6. Can the W1 circuit breaker be used at high altitudes or extreme temperatures?
The standard operating environment is -5°C to +40°C at altitudes ≤2000m. However, specialized derivatives are available to extend the working temperature from -40°C to +70°C, and custom insulation upgrades can adapt the unit for higher altitudes.