MNS Low Voltage Withdrawable Switchgear
Product Overview
Product Overview
The MNS series low-voltage withdrawable switchgear is a modular, prefabricated (FBA) assembly-type cabinet constructed with standard modules.
This series of low-voltage withdrawable switchgear is applicable to power plants, substations, petrochemical industry,metallurgical steelmaking, transportation energy, light textile industry and other industrial and mining enterprises, as well as residential areas, high-rise buildings and other places. It is used for the electrical energy conversion, distribution and control of power distribution equipment in power systems with an AC frequency of 50 - 60Hz and a rated working voltage of AC 660V and below.
This device complies with GB 7251.1 《Low-voltage switchgear and controlgear assemblies) and JB/T 9961 《Low-voltage withdrawable complete switchgear》national professional standards, and also conforms to IEC 61439-1 (note: IEC 439 has been replaced by IEC 61439, here it is corrected to the latest standard), VDE 0660 Part 5 and other international professional standards.
Conditions Of Use
Conditions Of Use
- The ambient air temperature shall not be higher than +40 ℃ and not lower than - 5 °C, and the average temperature within 24h shall not be higher than +35°C.
- The relative humidity of the surrounding air shall not exceed 50% when the maximum temperature is +40 °C, and there is a relatively high relative humidity when the temperature is low, such as 90% when the temperature is +20 °C. However, due to the change of temperature, moderate condensation may occasionally occur.
- For indoor use, the altitude of the place of use shall not exceed 2000m.
- It shall be installed in a place where there is no violent vibration and impact and where electrical components are not corroded.
Main Technical Parameters
| Project | Parameter |
| Rated insulation voltage | 660V(1000)V |
| Rated operating voltage | 380V、660V |
| Maximum working current of main bus | 5000A |
| Rated withstand current of main bus | 100kA/1s |
| Rated peak withstand current of main bus | 220kA/0.1s |
| Maximum working current of distribution bus (vertical bus) | 1000A |
| Peak current of distribution bus (vertical bus) - Standard | 105kA(Max.)/0.1s |
| Peak current of distribution bus (vertical bus) - Enhanced | 176kA(Max.)/0.1s |
Cabinet Structure
Cabinet Structure
The basic structure of the switchgear cabinet is composed of C profile assembly. Section C is made of steel plate with E=25mm module mounting hole. All cabinets and inner partitions are galvanized and purified. Around the door panels, the side panels are made of high voltage electrostatic spray. The basic structure of the cabinet is shown in Figure 1; the basic size of the cabinet is shown in the figure
Switch Cabinet Type
Switch Cabinet Type
- Power distribution center distance (PC): Emax, MT,3WN, AH, ME series circuit breakers can be adopted.
- Motor Control Center Cabinet (MCC) : Assembledfrom large and small drawers, the main switches of each circuit adopt high-breaking capacity molded case circuit breakers or rotary Load Switches with fuses. Power factor automatic compensation cabinet (equipped with manual, automatic and remote power factor compensation devices)
A Power Distribution Center (PC) Cabinet
| High | Wide | Deep | Remark | ||
| H | B | T | T1 | T2 | |
| 2200 | 400 | 1000 | 800 | 200 | Main bus switch |
| 2200 | 400 | 1000 | 800 | 200 |
F1s-1250-2000 ME630-1605 |
| 2200 | 600 | 1000 | 800 | 200 | F2s-2500 |
| 2200 | 800 | 1000 | 800 | 200 |
F4s-3200 ME2000-3200 |
| 2200 | 1000 | 1000 | 800 | 200 |
F5s-4000 ME3205 |
| 2200 | 1200 | 1000 | 800 | 200 | ME4005 |
B Motor Control Center (MCC) Cabinet
| High | Wide | Deep | Remark | ||||
| H | B | B1 | B2 | T | T1 | T2 | |
| 2200 | 1000 | 600 | 400 | 600 | 400 | 200 | One side operation |
| 2200 | 1000 | 600 | 400 | 1000 | 400 | 200 | Double-sided operation |
Cabinet frame Structure Composed Of C-shaped Profiles
Cabinet frame Structure Composed Of C-shaped Profiles

Cabinet Diagram
Cabinet Diagram