How to Choose the Right Medium Voltage Switchgear for Industrial Projects
How to Choose the Right Medium Voltage Switchgear for Industrial Projects
Introduction
Selecting the right medium voltage switchgear is an important decision for industrial plants, commercial buildings, infrastructure projects, renewable energy facilities, and other power distribution systems.
For project owners, electrical contractors, and equipment buyers, the selection process should go beyond simply comparing prices and rated voltage. The right switchgear should match the project's voltage level, load requirements, short-circuit capacity, installation environment, protection requirements, applicable standards, and future expansion plans.
A suitable configuration can improve power distribution reliability, operational safety, maintenance efficiency, and overall project performance.
This guide explains the key factors buyers should consider when selecting medium voltage switchgear and how different switchgear solutions can be matched to specific project requirements.

1. Key Factors to Consider When Selecting Medium Voltage Switchgear
Before requesting a quotation from a switchgear manufacturer, buyers should define several basic technical requirements.
1.1 Rated Voltage
Rated voltage is one of the first parameters to consider.
Common medium voltage switchgear applications include:
- 10kV / 12kV distribution systems
- 20kV / 24kV distribution systems
- 35kV / 40.5kV distribution systems
The switchgear's rated voltage should be compatible with the project's electrical network and equipment.
For example, 12kV switchgear is widely used in industrial and commercial power distribution systems. For indoor 12kV applications, a metal-enclosed switchgear solution such as KYN28-12 can be considered where reliable protection and flexible operation are required.
[Internal Link: KYN28-12 High Voltage Metal Enclosed Switchgear]
1.2 Rated Current
Rated current should be selected according to the actual electrical load of the project.
The calculation should consider:
- Transformer capacity
- Motor loads
- Distribution loads
- Existing electrical demand
- Expected future expansion
- Busbar capacity
It is not always necessary to select the highest available current rating. Instead, the equipment should provide sufficient capacity while maintaining an appropriate margin for future development.
For large industrial projects, the switchgear manufacturer may need to review the project's load list and single-line diagram (SLD) before recommending the final configuration.
1.3 Short-Circuit Withstand Capacity
Short-circuit performance is another critical factor in switchgear selection.
Buyers should pay attention to parameters such as:
- Short-time withstand current
- Peak withstand current
- Short-circuit breaking current
- Short-circuit duration
- Circuit breaker breaking capacity
The required values should be determined according to the project's electrical system and fault-level calculations.
For this reason, simply selecting switchgear based on voltage and rated current may not be sufficient for an industrial project.
2. Consider the Installation Environment
The operating environment has a direct influence on switchgear design and configuration.
Indoor Applications
Indoor switchgear is commonly used in:
- Manufacturing plants
- Commercial buildings
- Power distribution rooms
- Data centers
- Industrial facilities
- Infrastructure projects
The equipment may need to consider environmental factors such as temperature, humidity, dust, altitude, ventilation, and available installation space.
For projects with limited space, compact switchgear solutions may offer advantages in equipment-room layout and maintenance access.
Outdoor Applications
Outdoor power distribution equipment may require additional protection against:
- Rain
- Dust
- Temperature changes
- Solar radiation
- Moisture
- Corrosive environments
Depending on the project, the manufacturer may need to provide an appropriate enclosure, protection level, ventilation system, or other environmental adaptations.
3. Choose the Right Type of Medium Voltage Switchgear
Different projects require different switchgear configurations.
Instead of asking only "What is the cheapest switchgear?", buyers should ask:
"Which switchgear configuration is most suitable for my electrical system?"
The following table provides a simplified selection reference.
| Project Requirement | Possible Switchgear Solution |
|---|---|
| Indoor 12kV power distribution | KYN28-12 |
| Higher-voltage industrial distribution | KYN61-40.5 |
| Ring network power distribution | RMU / XGN series |
| Compact gas-insulated distribution | GIS / gas-insulated switchgear |
| SF₆-free environmental requirements | HBG-12 green gas insulated switchgear |
| Industrial power distribution | Metal-enclosed MV switchgear |
| Renewable energy projects | MV switchgear combined with transformers and substations |
The final selection should always be based on the project's electrical parameters and technical specifications.
4. KYN28-12 for 12kV Indoor Power Distribution
For industrial and commercial projects requiring indoor 12kV power distribution, KYN28-12 metal-enclosed switchgear is one possible solution.
It can be considered for applications such as:
- Industrial factories
- Commercial buildings
- Power distribution stations
- Infrastructure projects
- Mining and processing facilities
- Large electrical systems
The configuration can be designed according to project requirements, including incoming feeders, outgoing feeders, busbar arrangements, protection devices, metering equipment, and other electrical components.
For projects using a 12kV distribution system, buyers can provide the single-line diagram, rated current, short-circuit requirements, number of feeders, and project specifications to the manufacturer for technical evaluation.

→ [View KYN28-12 Metal Enclosed Switchgear]
5. KYN61-40.5 for Higher-Voltage Applications
For projects requiring higher-voltage distribution, a 40.5kV metal-enclosed switchgear solution may be considered.
KYN61-40.5 is designed for higher-voltage power distribution applications and can be used in industrial facilities and electrical substations where the system voltage and technical requirements call for a higher-voltage switchgear solution.
When selecting 40.5kV switchgear, buyers should pay particular attention to:
- Rated voltage
- Rated current
- Short-circuit capacity
- Busbar configuration
- Circuit breaker specifications
- Protection and control system
- Installation conditions
The final configuration should be determined according to the project's single-line diagram and technical specifications.

→ [View KYN61-40.5 High Voltage Metal Enclosed Switchgear]
6. When Should You Consider Green Gas Insulated Switchgear?
Environmental requirements are becoming increasingly important in modern power distribution projects.
Traditional SF₆ gas has been widely used in gas-insulated electrical equipment because of its excellent insulation and arc-extinguishing properties. However, its high global warming potential has encouraged the development and adoption of more environmentally friendly alternatives.
For projects with specific environmental requirements, SF₆-free or green gas insulated switchgear can be considered.
BOKONG's HBG-12 Green Gas Insulated Switchgear is designed as an environmentally friendly alternative for medium-voltage distribution applications.
It can be considered for projects where buyers are looking for:
- SF₆-free insulation technology
- Compact switchgear design
- Reliable medium-voltage distribution
- Reduced environmental impact
- Modern power distribution solutions

→ [View HBG-12 Green Gas Insulated Switchgear]
7. Why Certifications and Test Reports Matter
For international electrical projects, technical compliance is often just as important as the equipment itself.
Before purchasing medium voltage switchgear, buyers should confirm whether the supplier can provide relevant documentation, such as:
- IEC standards compliance
- GB standards compliance
- Type test reports
- Factory test reports
- Quality management certification
- Product certifications
- Factory inspection documentation
For overseas projects, customers may also have additional requirements related to local electrical regulations, project specifications, or third-party inspection.
Therefore, it is recommended that buyers confirm the required standards before production begins, rather than waiting until the equipment is ready for shipment.
BOKONG provides electrical equipment manufactured according to applicable international and Chinese standards, with relevant certifications, test reports, and technical documentation available according to the product and project requirements.
8. Customization Requirements for Industrial Projects
Standard switchgear configurations may not always meet the requirements of a specific project.
Industrial and infrastructure projects may require customized solutions involving:
- Cabinet dimensions
- Busbar configuration
- Rated current
- Incoming and outgoing feeders
- Cable entry direction
- Circuit breaker configuration
- Protection relays
- Metering devices
- Control systems
- Communication interfaces
- Interlocking systems
- Auxiliary components
For example, a project may require several incoming cabinets, multiple outgoing feeder cabinets, PT cabinets, bus-section cabinets, or specific protection and measurement configurations.
In these cases, working directly with an experienced switchgear manufacturer can make the technical communication and customization process more efficient.
9. What Information Should You Provide When Requesting a Switchgear Quotation?
To receive an accurate quotation, buyers should provide as much technical information as possible.
The following information is particularly useful:
Basic Project Information
- Project location
- Application
- Quantity
- Delivery destination
Electrical Parameters
- Rated voltage
- Rated current
- Frequency
- Short-circuit current
- Transformer capacity
- System grounding requirements
Switchgear Configuration
- Number of incoming feeders
- Number of outgoing feeders
- Bus-section requirements
- Circuit breaker type
- Protection requirements
- Metering requirements
- Communication requirements
Technical Documents
If available, buyers should provide:
- Single-line diagram (SLD)
- Technical specification
- Equipment schedule
- Layout drawing
- Load list
- Applicable standards
The more complete the information, the easier it is for the manufacturer to recommend a suitable configuration and prepare a more accurate quotation.
10. How to Select a Reliable Medium Voltage Switchgear Manufacturer
Price is important, but it should not be the only factor when evaluating a supplier.
For international projects, buyers should consider:
Manufacturing Capability
Check whether the supplier has its own manufacturing facilities, production equipment, testing equipment, and quality-control procedures.
Technical Capability
A reliable supplier should be able to understand electrical drawings, project specifications, protection requirements, and customized configurations.
Certifications and Testing
Check the manufacturer's available certifications, test reports, and quality-management systems.
Project Experience
Experience with international projects can help reduce communication problems and technical risks.
After-Sales Support
For large projects, technical support during installation, commissioning, and operation can be important.
Customization Capability
The supplier should be able to adapt the equipment to the project's actual requirements instead of simply supplying a standard product.
11. BOKONG Medium Voltage Switchgear Solutions
As a manufacturer of power transmission and distribution equipment, BOKONG Electric provides medium- and high-voltage electrical equipment for industrial, commercial, infrastructure, and other power distribution applications.
Our product range includes different switchgear and power distribution solutions, including:
- KYN28-12 metal-enclosed switchgear
- KYN61-40.5 high-voltage switchgear
- GIS gas-insulated switchgear
- RMU / ring main unit solutions
- HBG-12 SF₆-free green gas insulated switchgear
- GGD low-voltage switchgear
- MNS withdrawable switchgear
- Box-type substations
- Distribution transformers
Different configurations can be developed according to project requirements, technical specifications, electrical drawings, and customer needs.
For project inquiries, customers can provide their single-line diagram, technical specifications, required quantity, voltage level, current rating, and destination so that our technical team can evaluate the application and recommend a suitable solution.
Frequently Asked Questions
What is medium voltage switchgear?
Medium voltage switchgear is electrical distribution equipment used to control, protect, isolate, and distribute electrical power in medium-voltage power systems.
How do I choose the correct medium voltage switchgear?
The selection should consider rated voltage, rated current, short-circuit capacity, installation environment, protection requirements, applicable standards, available space, and future expansion requirements.
What is the difference between KYN28-12 and KYN61-40.5?
The main difference is their applicable voltage level. KYN28-12 is designed for 12kV-class applications, while KYN61-40.5 is intended for higher-voltage applications up to the 40.5kV class. The final selection should be based on the project's electrical system.
Can medium voltage switchgear be customized?
Yes. Switchgear can be customized according to requirements such as cabinet dimensions, rated current, feeder configuration, busbar arrangement, protection devices, metering, control systems, and communication functions.
What documents are required for a switchgear quotation?
A single-line diagram, technical specification, rated voltage, rated current, short-circuit requirements, feeder quantity, application, quantity, and delivery destination are useful for preparing an accurate quotation.
What certifications should I check when purchasing MV switchgear?
Depending on the project and destination market, buyers may need to check IEC or applicable national standards, type-test reports, factory test reports, quality certifications, and other project-specific documentation.
Can medium voltage switchgear be used for renewable energy projects?
Yes. Medium voltage switchgear can be integrated into power distribution systems for solar, wind, energy storage, and other renewable energy projects. The configuration should be selected according to the project's voltage level, power capacity, protection requirements, and grid-connection conditions.
Conclusion
Choosing the right medium voltage switchgear requires more than comparing product prices. A suitable solution should match the project's voltage, current, short-circuit capacity, installation environment, protection requirements, applicable standards, and future development plans.
For industrial and commercial projects, buyers can evaluate different solutions such as KYN28-12, KYN61-40.5, RMU, GIS, and SF₆-free green gas insulated switchgear according to their specific requirements.
Providing complete technical information at the beginning of the procurement process can help manufacturers recommend the right configuration, reduce unnecessary communication, and improve quotation accuracy.
Looking for a medium voltage switchgear solution for your project? Send us your single-line diagram or technical specification, and our team can help evaluate the appropriate configuration.
