Introduction
When purchasing medium voltage switchgear, buyers usually focus on rated voltage, rated current, short-circuit capacity and cabinet dimensions. However, the components installed inside the cabinet are equally important.
These components work together to provide power distribution, switching, measurement, protection and operational safety.
A typical configuration may include a vacuum circuit breaker, main busbar, CT, VT/PT, protection relay, operating mechanism and interlocking system.
1. Six Key Components Inside Medium Voltage Switchgear
|
01 · SWITCHING
Vacuum Circuit BreakerSwitches normal operating current and interrupts fault current when necessary. |
02 · POWER DISTRIBUTION
Main BusbarProvides the main electrical path for distributing power between circuits. |
|
03 · MEASUREMENT
CT & VTProvide current and voltage signals for measurement, monitoring and protection. |
04 · PROTECTION
Protection RelayDetects abnormal electrical conditions and sends trip commands when required. |
|
05 · OPERATION
Operating MechanismControls the opening and closing operation of the circuit breaker. |
06 · SAFETY
Interlocking MechanismHelps prevent incorrect operating sequences and improves operational safety. |
2. What Do These Components Do?
Vacuum Circuit Breaker
The Vacuum Circuit Breaker (VCB) is one of the most important switching components in medium voltage switchgear. Buyers should check rated voltage, rated current, short-circuit breaking current, operating mechanism, endurance and control voltage.
For 12kV applications, the circuit breaker should be selected according to the project's load and short-circuit requirements. See our KYN28-12 Medium Voltage Switchgear.
Busbar
The busbar provides the main electrical path between incoming and outgoing circuits. Important factors include material, rated current, cross-sectional area, insulation, temperature rise and short-time withstand current.
CT and VT
Current Transformers (CTs) and Voltage Transformers (VTs/PTs) provide signals for measurement and protection. Key selection parameters include transformation ratio, accuracy class, rated burden and primary/secondary voltage.
Protection Relay
The protection relay monitors electrical conditions such as overcurrent, short circuit and earth fault. When a fault is detected, it can send a trip signal to the circuit breaker.
Operating & Interlocking Mechanisms
The operating mechanism controls circuit breaker opening and closing. The interlocking mechanism helps prevent unsafe operating sequences between the circuit breaker, disconnecting mechanism and earthing switch.
3. What Should Buyers Check Before Ordering?
Before placing an order, buyers should confirm both the electrical parameters and the internal component configuration.
| Item | What to Check |
|---|---|
| Rated Voltage | 6kV, 10kV, 12kV, 24kV, 35kV, etc. |
| Rated Current | Required continuous operating current |
| Short-Circuit Capacity | Required fault withstand/breaking capability |
| Circuit Breaker | VCB type and specifications |
| CT / VT | Ratio, accuracy and protection requirements |
| Protection | Protection relay and control requirements |
| Cabinet | Dimensions, cable entry and configuration |
| Safety | Earthing and interlocking system |
BOKONG Medium Voltage Switchgear Solutions
BOKONG Electric provides medium voltage and high voltage power distribution equipment for industrial and infrastructure applications.
Different combinations of circuit breakers, CTs, VTs, protection systems, operating mechanisms and interlocking systems can be considered according to project requirements.
Frequently Asked Questions
Common components include vacuum circuit breakers, busbars, CTs, VTs/PTs, protection relays, operating mechanisms and interlocking systems.
A VCB switches normal operating current and interrupts fault current when required, providing an important switching and protection function.
Yes. Cabinet configuration, electrical components, protection systems and mechanical arrangements can be selected according to project specifications and customer requirements.
Need a Customized Medium Voltage Switchgear Solution?
Send us your voltage level, rated current, single-line diagram and technical requirements. Our team can help evaluate the required configuration.
Contact BOKONG Electric →