Introduction

When purchasing medium voltage switchgear, buyers usually focus on rated voltage, rated current, short-circuit capacity and cabinet dimensions. However, the components installed inside the cabinet are equally important.

These components work together to provide power distribution, switching, measurement, protection and operational safety.

So, what are the key components inside a typical medium voltage switchgear cabinet?
A typical configuration may include a vacuum circuit breaker, main busbar, CT, VT/PT, protection relay, operating mechanism and interlocking system.

1. Six Key Components Inside Medium Voltage Switchgear

01 · SWITCHING

Vacuum Circuit Breaker

Switches normal operating current and interrupts fault current when necessary.

02 · POWER DISTRIBUTION

Main Busbar

Provides the main electrical path for distributing power between circuits.

03 · MEASUREMENT

CT & VT

Provide current and voltage signals for measurement, monitoring and protection.

04 · PROTECTION

Protection Relay

Detects abnormal electrical conditions and sends trip commands when required.

05 · OPERATION

Operating Mechanism

Controls the opening and closing operation of the circuit breaker.

06 · SAFETY

Interlocking Mechanism

Helps prevent incorrect operating sequences and improves operational safety.


2. What Do These Components Do?

Vacuum Circuit Breaker

The Vacuum Circuit Breaker (VCB) is one of the most important switching components in medium voltage switchgear. Buyers should check rated voltage, rated current, short-circuit breaking current, operating mechanism, endurance and control voltage.

For 12kV applications, the circuit breaker should be selected according to the project's load and short-circuit requirements. See our KYN28-12 Medium Voltage Switchgear.

Busbar

The busbar provides the main electrical path between incoming and outgoing circuits. Important factors include material, rated current, cross-sectional area, insulation, temperature rise and short-time withstand current.

CT and VT

Current Transformers (CTs) and Voltage Transformers (VTs/PTs) provide signals for measurement and protection. Key selection parameters include transformation ratio, accuracy class, rated burden and primary/secondary voltage.

Protection Relay

The protection relay monitors electrical conditions such as overcurrent, short circuit and earth fault. When a fault is detected, it can send a trip signal to the circuit breaker.

Fault → CT / VT → Protection Relay → Trip Signal → Circuit Breaker

Operating & Interlocking Mechanisms

The operating mechanism controls circuit breaker opening and closing. The interlocking mechanism helps prevent unsafe operating sequences between the circuit breaker, disconnecting mechanism and earthing switch.


3. What Should Buyers Check Before Ordering?

Before placing an order, buyers should confirm both the electrical parameters and the internal component configuration.

Item What to Check
Rated Voltage 6kV, 10kV, 12kV, 24kV, 35kV, etc.
Rated Current Required continuous operating current
Short-Circuit Capacity Required fault withstand/breaking capability
Circuit Breaker VCB type and specifications
CT / VT Ratio, accuracy and protection requirements
Protection Protection relay and control requirements
Cabinet Dimensions, cable entry and configuration
Safety Earthing and interlocking system
Providing a single-line diagram, technical specification or equipment list can help the manufacturer recommend a more suitable configuration.

BOKONG Medium Voltage Switchgear Solutions

BOKONG Electric provides medium voltage and high voltage power distribution equipment for industrial and infrastructure applications.

1.HBG-12 Environmental Protection Gas Insulated Switchgear.jpg 3.RM6-24 Ring Main Unit SF6 Gas-Insulated Switchgear.png

HBG-12 Environmental Protection Gas Insulated Switchgear

RM6-40.5 Ring Main Unit SF6 Gas-Insulated Switchgear

rm6-12-front.webp 1.RM6-12-Ring-Main-Unit-SF6-Gas-Insulated-Switchgear.jpg

XGN15 Series Fixed Metal-Enclosed Ring Main Unit

RM6-12 Ring Main Unit SF6 Gas-Insulated Switchgear

Different combinations of circuit breakers, CTs, VTs, protection systems, operating mechanisms and interlocking systems can be considered according to project requirements.


Frequently Asked Questions

1.What are the main components inside medium voltage switchgear?

Common components include vacuum circuit breakers, busbars, CTs, VTs/PTs, protection relays, operating mechanisms and interlocking systems.

2.What does a vacuum circuit breaker do?

A VCB switches normal operating current and interrupts fault current when required, providing an important switching and protection function.

3.Can medium voltage switchgear be customized?

Yes. Cabinet configuration, electrical components, protection systems and mechanical arrangements can be selected according to project specifications and customer requirements.


Need a Customized Medium Voltage Switchgear Solution?

Send us your voltage level, rated current, single-line diagram and technical requirements. Our team can help evaluate the required configuration.

Contact BOKONG Electric →
BOKONG ELECTRIC CO., LTD. · Medium & High Voltage Power Distribution Solutions