YUEQING, CHINA — August 13, 2026 — BOKONG ELECTRIC has introduced its MNS low voltage withdrawable switchgear, a modular power distribution solution designed for demanding electrical environments including power plants, petrochemical facilities, metallurgical plants, textile factories, and high-rise buildings. Designed for three-phase 50/60 Hz systems at 380V, 400V and 660V, the MNS withdrawable switchgear combines modular withdrawable units, high interchangeability, high circuit density and enhanced electrical protection to support reliable power distribution and motor control.

With a rated operating voltage of 400V/660V and rated insulation voltage of 660V/1000V, the system supports horizontal busbar currents up to 5000A and short-time withstand currents of 50kA, 65kA and 80kA for 1 second. Its peak withstand current reaches 105kA, 140kA and 176kA for 0.1 second, providing a robust solution for industrial power distribution systems.

MNS Low Voltage Withdrawable Switchgear.png

Four Key Advantages for Industrial Power Distribution

1. Modular Withdrawable Drawer Structure for Easier Maintenance

The MNS switchgear adopts a modular withdrawable drawer structure that allows individual functional units to be isolated from the main system. This design helps limit the impact of localized faults and enables maintenance or replacement of individual units with reduced interruption to other circuits.

For facilities where continuous operation is critical, such as power plants, petrochemical production lines and data-intensive industrial facilities, the modular configuration can help improve operational flexibility and maintenance efficiency.

2. High-Interchangeability Withdrawable Units with Mechanical Interlocking

The withdrawable functional units are designed for high interchangeability, simplifying configuration, replacement and maintenance.

Mechanical interlocking mechanisms help prevent incorrect operating sequences and improve operational safety. The combination of standardized drawer units and mechanical interlocking makes the system suitable for highly automated electrical distribution environments and computer-interface control systems.

High-Interchangeability Withdrawable Units with Mechanical Interlocking.png

3. Up to 22 Circuits per Cabinet for Space-Efficient Distribution

A single cabinet can accommodate up to 22 circuits, allowing multiple distribution and control functions to be integrated into a compact footprint.

Compared with conventional layouts requiring more independent cabinets, the high circuit density can potentially reduce installation space by more than 30%, depending on the specific system configuration. This makes the MNS solution particularly valuable where electrical rooms have strict space limitations.

MNS Low Voltage Withdrawable Switchgear-1 .png

4. Overvoltage Category IV for Demanding Electrical Environments

The MNS low voltage switchgear is designed for Overvoltage Category IV and Pollution Degree 3, supporting applications exposed to demanding electrical and environmental conditions.

The system is suitable for indoor installation at altitudes up to 2,000 meters, with an ambient temperature range from -5°C to +40°C and a daily average temperature not exceeding +35°C.

Designed for Power Distribution, Motor Control and Reactive Power Compensation

The MNS system integrates three major functions within a common low voltage switchgear platform:

  • Electrical power distribution

  • Centralized motor control

  • Reactive power compensation

The vertical busbar supports a maximum operating current of 1000A, with a short-time withstand current of 50kA and a peak withstand current of 105kA.

This configuration enables engineers to develop flexible low voltage distribution architectures for industrial plants, infrastructure facilities and commercial buildings.

Application Areas

MNS withdrawable switchgear is designed for applications including:

  • Power plants — main and auxiliary low voltage power distribution and motor control

  • Petrochemical facilities — reliable power distribution for petrochemical production systems

  • Metallurgical plants — centralized motor control and high-current power distribution

  • Textile factories — low voltage distribution and production equipment control

  • High-rise buildings — centralized building power distribution and electrical control

For petrochemical and other process industries, the combination of modular withdrawable units, high current capacity and mechanical interlocking provides a practical approach to organizing complex low voltage electrical systems.

Technical Specifications

Parameter Specification
Product MNS Low Voltage Withdrawable Switchgear
Application System 3-phase, 50/60 Hz
Rated Operating Voltage 400V / 660V
Rated Insulation Voltage 660V / 1000V
Horizontal Busbar Rated Current ≤5000A
Horizontal Busbar Short-Time Withstand Current 50kA / 65kA / 80kA, 1s RMS
Horizontal Busbar Peak Withstand Current 105kA / 140kA / 176kA, 0.1s maximum
Vertical Busbar Maximum Operating Current ≤1000A
Vertical Busbar Short-Time Withstand Current 50kA
Vertical Busbar Peak Withstand Current 105kA
Maximum Circuits per Cabinet 22
Protection Degree IP30 / IP40
Dimensions 600/800/1000 × 800/1000 × 2200 mm
Overvoltage Category IV
Pollution Degree 3
Installation Indoor
Maximum Altitude ≤2000 m
Ambient Temperature -5°C to +40°C
Daily Average Temperature ≤+35°C
Standards GB7251.1-2005, IEC 60439

Addressing Reliability Challenges in Highly Automated Facilities

“For highly automated power plants and petrochemical facilities, the challenge is not simply delivering electrical power, but maintaining reliable distribution while reducing the impact of equipment faults and simplifying maintenance. Our MNS withdrawable switchgear is designed around this requirement, combining modular drawer technology, mechanical interlocking, high circuit density and enhanced electrical withstand capability.”

— Technical Director, BOKONG ELECTRIC

According to BOKONG ELECTRIC, the MNS platform is intended to provide electrical engineers and procurement teams with a flexible foundation for designing modern low voltage distribution systems where reliability, maintainability and efficient space utilization are key considerations.

Standards and Configuration Flexibility

The MNS switchgear complies with GB7251.1-2005 and IEC 60439 requirements. Its Overvoltage Category IV and Pollution Degree 3 classification further support applications requiring enhanced electrical environmental adaptability.

The standard protection levels are IP30 and IP40, while customized protection solutions can be considered according to specific project requirements.

With multiple cabinet dimensions, withdrawable unit configurations and functional arrangements available, the system can be configured according to project-specific requirements for power distribution, motor control and reactive power compensation.