1.Discharging Residual Energy: Cutting "Invisible Risks" in 0.1 Seconds

After an HV system is shut down, the line may still retain inductive charge equivalent to 30%-50% of the rated voltage. For a 10kV system alone, this residual energy can reach dozens of joules, enough to cause fatal electric shock. The core value of the JN15 earthing switch lies in forming a low-resistance path to the ground via its three-pole linked contacts, discharging the residual charge in 0.1 seconds and reducing the equipment shell potential to a safe range of ≤5V.

1.Why JN15 Earthing Switch Is a Must in HV Switchgear.jpg

Its copper alloy contacts have a contact resistance of ≤50μΩ, far lower than the industry standard of 100μΩ. With a dynamic stable current tolerance of 25kN, it avoids ablation even when exposed to a 40kA short-circuit impulse current. It fully meets the "1-minute 400A thermal stability" requirement in GB 1985 and IEC 62271-102 standards, building a physical barrier for maintenance personnel.

 

2.Misoperation Prevention Design: 100% Elimination of Fatal Accidents

In HV switchgear operation, two fatal misoperations—"closing with earthing engaged" and "operating the earthing switch under load"—account for 42% of HV accidents. The JN15 is equipped with a mechanical interlocking device that enforces locking with the HV circuit breaker: it can only close when the main circuit breaker is fully open (triggered by an auxiliary contact disconnection signal); conversely, when the earthing switch is closed, the breaker’s closing circuit is automatically cut off.

 

This "hard interlock" has a response time of <10ms, 100 times faster than manual verification. In substations with over 1,000 annual operations, it reduces misoperation risk from 0.3% to 0, making it an essential safety component for staff-intensive power distribution scenarios.

 

3.High Adaptability: Covering Over 90% of HV Switchgear Models

The JN15 features a modular design, with installation dimensions compatible with mainstream 10kV-35kV switchgear such as KYN28 and XGN15-12. No additional cabinet modification is required, achieving an adaptability rate of 92%. It supports both manual (operating torque ≤80N·m) and electric (action time ≤1.5s) operation modes. The electric version can be integrated into the IEC 61850 smart power distribution system for remote monitoring of opening/closing status.

 

For extreme environments, its customized version uses a 304 stainless steel enclosure and F46 anti-corrosion coating, operating stably at -40℃~+40℃ and 95% humidity. Its service life exceeds 15 years in corrosive scenarios like coastal areas and chemical plants, 50% longer than ordinary earthing switches.

 